LC Quad shutter adapter internal shutter adapter
Competitive Advantage:
Telcordia GR-326, IEC, TIA/EIA Standard compliant.
100% Optical performance inspection.
Low Insertion Loss.
RoHS Compliance.
Customized design and production.
Parts |
Material |
Remarks |
Sleeve |
Zirconia, PB |
|
Housing |
PC |
Flammability UL94 V-0 |
Dust cap |
PC、PP/PE |
Flammability UL94 V-0 |
Shutter |
Stainless Steel |
Flammability UL94 V-0 |
Metal Clip |
Stainless Steel |
|
1. Optical fiber communication system |
2. Limited TV network |
3. LAN and optical domain network |
4. Fiber to the Home (FTTP) |
5. Video transmission |
6. Test instrument |
Optical Performance | |||
Premium Grade | Standard Grade | ||
Insertion Loss | ≤0.1dB | ≤0.2dB | |
Durability | 1000 times | 1000 times | |
Enviroment and Mechanical | |||
Properties | Test condition | Conformance | Test result |
Vibration | 10-55Hz, 1.5mm, 60min | IEC61300-2-1 | ≤0.2dB |
Mating Durability | 1000 Mating, clean every 25 mating. | IEC61300-2-2 | ≤0.2dB |
Impact | 1.5m, 8 drops | IEC61300-2-6 | ≤0.2dB |
Strength of Coupling Mechanism | 40N, 10Min, L=22-28cm | IEC61300-2-12 | ≤0.2dB |
Temperature Cycling | 40ºC to +75ºC, 40 cycles | IEC61300-2-22 | ≤0.2dB |
Temperature humidty cycling | 40ºC, 95%, 96Hr | IEC61300-2-21 | ≤0.2dB |
Operating Temperature | -40ºC to +85ºC | ≤0.2dB | |
Storage Temperature | -40ºC to +85ºC | ≤0.2dB |